23

8-2.

Outdoor Unit (In

ver

ter Assemb

ly

)

RAS-10GA

VP-E,

RAS-13GA

VP-E,

RAS-16GA

VP-E

220–240 V

~

50Hz

220 V

~

60Hz

MICRO-COMPUTER BLOCK DIAGRAM

Driver circuit

of P.M.V.

Heat exchanger

temp.sensor

Suction temp.

sensor

Outdoor air

temp. sensor

Discharge

temp. sensor

Indoor unit

send/receive

circuit

Relay
circuit

Noise

Filter

Converter

(AC

DC)

Clock

frequency

4MHz

High Power

factor Correction

circuit

Input current

sensor

• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• 4-way valve control
• Signal communication to indoor unit

P.M.V. : Pulse Motor Valve
M.C.U. : Micro Control Unit

M.C.U

For INDOOR UNIT

4-way

valve

P.M.V.

Inverter

(DC

AC)

Gate drive

circuit

Gate drive

circuit

Inverter

(DC

AC)

Outdoor

Fan motor

Compressor

MCC5009 (P.C.B)

OUTDOOR UNIT

Current

detect

Current

detect