2. outdoor unit (in ver ter assemb ly ), Micro-computer block diagram – Toshiba RAS-B13GKVP-E User Manual
Page 23
–
23
–
8-2.
Outdoor Unit (In
ver
ter Assemb
ly
)
RAS-10GA
VP-E,
RAS-13GA
VP-E,
RAS-16GA
VP-E
220–240 V
~
50Hz
220 V
~
60Hz
MICRO-COMPUTER BLOCK DIAGRAM
Driver circuit
of P.M.V.
Heat exchanger
temp.sensor
Suction temp.
sensor
Outdoor air
temp. sensor
Discharge
temp. sensor
Indoor unit
send/receive
circuit
Relay
circuit
Noise
Filter
Converter
(AC
→
DC)
Clock
frequency
4MHz
High Power
factor Correction
circuit
Input current
sensor
• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• 4-way valve control
• Signal communication to indoor unit
P.M.V. : Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way
valve
P.M.V.
Inverter
(DC
→
AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC
→
AC)
Outdoor
Fan motor
Compressor
MCC5009 (P.C.B)
OUTDOOR UNIT
Current
detect
Current
detect