– 30 –

Item

3. Outdoor fan

motor control

Operation flow and applicable data, etc.

The blowing air volume at the outdoor unit side is controlled.

Receiving the operation command from the controller of
indoor unit, the controller of outdoor unit controls fan speed.

* For the fan motor, a DC motor with non-stage variable

speed system is used. However, it is limited to 8 stages for
reasons of controlling.

Description

1) The operation command sent

from the remote controller is
processed by the indoor unit
controller and transferred to the
controller of the outdoor unit.

2) When strong wind blows at

outdoor side, the operation of air
conditioner continues with the
fan motor stopped.

3) Whether the fan is locked or not

is detected, and the operation of
air conditioner stops and an
alarm is displayed if the fan is
locked.

4) According to each operation

mode, by the conditions of
outdoor temperature (To) and
compressor revolution, the speed
of the outdoor fan shown in the
table is selected.

Outdoor fan speed (rpm)

Tap

f 1

f 2

f 3

f 4

f 5

f 6

f 7

f 8

10GAVP-E

13GAVP-E

16GAVP-E

200

200

200

300

300

300

390

390

390

450

450

450

500

500

500

500

500

500

600

600

600

600

600

600

Tap

f 9

f A

f B

f C

f D

f E

f F

10GAVP-E

13GAVP-E

16GAVP-E

700

700

700

700

700

700

700

700

700

700

700

700

750

840

920

750

840

920

750

840

920

2) Fan speed

400

when the motor stopped.

Air conditioner ON

(Remote controller)

YES

YES

NO

NO

Indoor unit controller

Fan motor ON

3) Fan lock

OFF status of

fan motor continues.

4) Motor operates as shown in the table below.

1) Outdoor unit
operation

command

(Outdoor

fan

control)

Air conditioner

OFF

Alarm

display

Compressor speed (rps)

To > 38°C

To > 28°C

To

To > 15°C

To > 5.5°C

To > 0°C

During

To > 38°C

ECO mode

To < 38°C

When To is abnormal

~ 13.8

~ 31.7

32.3 ~ MAX

MIN MAX MIN MAX MIN MAX

f 2

f 3

f C

f D

f E

f F

f 2

f 3

f B

f C

f E

f F

f 2

f 3

f 8

f 9

f A

f B

f 2

f 3

f 6

f 7

f 8

f 9

f 1

f 2

f 4

f 5

f 6

f 7

f 2

f 3

f B

f C

f C

f D

f 2

f 3

f 2

f 3

f B

f C

f D

f F

f D

f F

f D

f F

In cooling operation

Compressor speed (rps)

To > 15°C

To

To < 15°C

To < 5.5°C

To < –5.0°C

To > 15°C

During

To < 15°C

ECO mode

To < 5.5°C

To < –5.5°C

When To is abnormal

~16.8 ~47.9 48.5 ~ MAX

f 3

f 8

f 9

f 3

f 9

f A

f 8

f A

f D

f B

f C

f D

f 3

f 3

f 6

f 3

f 3

f 8

f 5

f 9

f 9

f 7

f A

f B

f A

f B

f D

In Heating operation