beautypg.com

Toshiba RAS-B13GKVP-E User Manual

Page 29

background image

– 29 –

Item

2. Indoor fan

motor control

Operation flow and applicable data, etc.

Description

1) When setting the fan speed to L,

L+, M, M+ or H on the remote
controller, the operation is per-
formed with the constant speed
shown in Fig. 3 and Table 1.

2) When setting the fan speed to

AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 5 according to the set
temperature and room temperature.

3) Min air flow rate is controlled by

temperature of the indoor heat
exchanger (Tc) as shown in Fig. 4.

4) Cold draft prevention, the fan

speed is controlled by temperature
of the indoor heat exchanger (Tc)
as shown in Fig. 6.

[In starting and in stability]

(Fig. 3)

(Fig. 4)

(Fig. 5)

Cold draft preventive control

(Fig. 6)

Fan speed

AUTO

Basic fan control

* No limitation while fan speed MANUAL mode is in stability.
* A: When Tsc

24, A is 24, and when Tsc < 24, A is Tsc

Tsc: Set value

TSC

TA

[˚C]

b

–0.5

c

–1.0

d

–1.5

e

–2.0

f

–2.5

g

–5.0

–5.5

L (W8)

M+ (WD)

*1

*2

*3

H (WE)

H (WE)

Line-approximate
H and SUL with Tc.

SUL (W2)

Stop

46

46

Tc

34

45

45

33

33

33

21

32

32

20

*A+4

*A+4

*A+4

*A-4

*A-4

*A-4

Fan speed MANUAL in starting
Fan speed AUTO in stability
Fan speed AUTO in starting

L

L+

M

M+

H

W8

(L + M) / 2

WA

(M + H) / 2

WE

Indication

Fan speed

Fan speed setup

HEAT ON

AUTO

YES

NO

MANUAL

TC

42˚C

Min air flow rate control

Tc

52
51

42
41

Limited to Min WD tap

* Fan speed =

(TC –

– W8) + W8

No limit

*

*1:

4 + L

*2:

4 + L

FAN AUTO

FAN Manual

In starting

• Until 12 minutes passed after operation start
• When 12 to 25 minutes passed after operation

start and room temp. is 3°C or lower than set temp.

• Room temp. < Set temp. –4°C

In stability

• When 12 to 25 minutes passed after operation start

and room temp. is higher than (set temp. –3°C)

• When 25 minutes or more passed after operation start

• Room temp.

Set temp. –3.5°C

This manual is related to the following products: