– 51 –

When the installation plate is directly
mounted on the wall

1. Securely fit the installation plate onto the wall by

screws with the upper and lower catches, that
hold the indoor unit, facing out.

2. To mount the installation plate on a concrete wall

use anchor bolts. Drill the anchor bolt holes as
illustrated in the above figure.

3. Install the installation plate horizontally and level.

CAUTION

When installing the installation plate with mount-
ing screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in
personal injury and property damage.

Fig. 10-3-4

Fig. 10-3-5

CAUTION

Failure to securely install the unit may result in
personal injury and/or property damage if the
unit falls.

• In case of block, brick, concrete or similar type

walls, drill 5 mm dia. holes in the wall.

• Insert clip anchors for the

‡

mounting screws.

NOTE :

• Install the installation plate using mounting screws

between 4 to 6, being sure to secure all four
corners.

Anchor bolt

Projection
15mm or less

5 mm dia. hole

Clip anchor
(local parts)

7 Mounting screw
Ш4 Ч 25L

10-3-3. Electrical Work

1. The supply voltage must be the same as the

rated voltage of the air conditioner.

2. Prepare a power source for the exclusive use of

the air conditioner.

NOTE :

• Wire type :

More than H07RN-F or 245IEC66 (1.0mm²)

CAUTION

• This appliance can be connected to a main

circuit breaker in either of the following two
ways.

1. Connection to fixed wiring:

A switch or circuit breaker which discon-
nects all poles and has a contact separa-
tion of at least 3 mm must be incorporated
in the fixed wiring. An approved circuit
breaker or switch must be used.

2. Connection with power supply plug:

Attach power supply plug with power cord
and plug it into wall outlet. An approved
power supply cord and plug must be used.

NOTE :

• Perform wiring work being sure the wire length is

long enough.

10-3-4. Wiring Connection

How to connect the connecting cable

Wiring the connecting cable can be carried
out without removing the front panel.

1. Remove the air inlet grille. Open the air inlet grille

upward and pull it toward you.

2. Remove the terminal cover and cord clamp.

3. Insert the connecting cable (or as according to

local regulations/codes) into the pipe hole on the
wall.

4. Pull the connecting cable through the cable slot

on the rear panel so that it protrudes about
15 cm out of the front.

5. Insert the connecting cable fully into the terminal

block and secure it tightly with screws.

6. Tightening torque: 1.2 N•m (0.12 kgf•m)

7. Secure the connecting cable with the cord clamp.

8. Attach the terminal cover, rear plate bushing and

air inlet grille on the indoor unit.

This manual is related to the following products: