CAUTION

• Be sure to refer to the wiring system diagram

labeled inside the front panel.

• Check local electrical regulations for any

specific wiring instructions or limitations.

10-3-5. Piping and Drain Hose Installation

Piping and drain hose forming

• Since condensation results in machine trouble,

make sure to insulate both the connecting pipes
separately.
(Use polyethylene foam as insulating material.)

Fig. 10-3-6

Fig. 10-3-7

Fig. 10-3-8

Fig. 10-3-9

NOTE :

WIRE TYPE : more than H07 RN-F or 245 IEC 66.
(1.0mm²)

Screw

Screw

Terminal cover

Cord clamp

Terminal block

Earth wire

Connecting cable

Terminal block

Connecting cable

About 15 cm

Earth line

70 mm

10 mm

10 mm

50 mm

Fig. 10-3-10

1. Die-cutting front panel slit

Cut out the slit on the left or right side of the front
panel for the left or right connection and the slit
on the bottom left or side of thefront panel for the
bottom left or right connection with a pair of
nippers.

2. Changing drain hose

For left connection, left-bottom connection and
rear-left connection’s piping, it is necessary to
relocate the drain hose and drain cap.

How to remove the drain cap

Clip drain cap with needle-nose pliers, and pull out.

Fig. 10-3-11

How to remove the drain hose

The drain hose is secured in place by a screw.

Remove the screw securing the drain hose, then pull
out the drain hose.