beautypg.com

2. operation data – Toshiba RAS-B13GKVP-E User Manual

Page 21

background image

– 21 –

7-2. Operation Data

Temperature

condition (°C)

Indoor

Outdoor

27/19

35/–

Model name

RAS-

B10GKVP-E

B13GKVP-E

B16GKVP-E

Standard

pressure

P (MPa)

0.9 to 1.1

0.8 to 1.0

0.7 to 0.9

Heat exchanger

pipe temp.

T1 (°C)

T2 (°C)

13 to 15

42 to 44

11 to 14

42 to 45

8 to 11

43 to 47

Indoor

fan mode

High

High

High

Outdoor

fan mode

High

High

High

Compressor

revolution

(rps)

37

59

82

Temperature

condition (°C)

Indoor

Outdoor

20/–

7/6

Model name

RAS-

B10GKVP-E

B13GKVP-E

B16GKVP-E

Standard

pressure

P (MPa)

2.2 to 2.4

2.5 to 2.7

2.8 to 3.0

Heat exchanger

pipe temp.

T1 (°C)

T2 (°C)

37 to 39

0 to 3

42 to 45

0 to 2

48 to 49

0 to 2

Indoor

fan mode

High

High

High

Outdoor

fan mode

High

High

High

Compressor

revolution

(rps)

54

65

86

NOTES :

1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.

(Thermistor themometer)

2. Connecting piping condition : 7.5 m