Setup & Installation

Card Installation Procedure

Figure 2-3 Battery/module tool.

Figure 2-4 Card being inserted.

1. Ground yourself using a wrist strap and anti-static mat.
2. Turn off the ISP-100.
3. Remove the screws securing the module slot cover.
4. If you are not replacing an existing card please proceed to step 6.
5. Use the battery/module removal tool to remove the existing module.

The battery/module removal tool is attached to the inside of the
front security cover. Place the hook end of the tool into the slot at
the bottom of the module and pull. Place the old module in an
anti-static bag. See Figure 2-3 for more information.

6. Being careful to avoid scraping the underside of the board, slide the

new module into the bottom slots on the card guides located
inside the opening. Push the module into the unit until you feel
resistance. See Figures 2-4 and 2-5.

7. Firmly push on the module’s faceplate to seat the module.
8. Replace the screws that were removed in step 3.
9. Turn on the ISP-100 and verify that the slot indicator for the module is

either solid green or blinking green. If the slot indicator is not
solid green or blinking green, then there is a problem with the
current hardware and/or software. Please refer to the
Troubleshooting section to identify the problem.