beautypg.com

Quantum ATL M-Series User Manual

Page 143

background image

Appendix B Fault Symptom Code (FSC) Dictionary

ATL M-Series User’s Guide

125

2413

FSC_LIBRARIAN_SRC_

ABSENT

Source slot not present

(magazine or drive

removed)

Microcode

100%

2414

FSC_LIBRARIAN_NO_
START_SLOT

Demo unable to select
random start slot (try

re-running demo)

Microcode

100%

2415

FSC_LIBRARIAN_

AUTOCLEAN_IN_

PROGRESS

Move medium

attempted to drive that

is being auto cleaned

Microcode

100%

2416

FSC_LIBRARIAN_BAD_

MESSAGE_PARAMETER

Bad parameter in

Librarian message

Microcode

100%

2417

FSC_LIBRARIAN_

DEDICATED_CLEANER

Fixed slot reserved for

dedicated cleaner; not

for general use

Microcode

100%

2418

FSC_LIBRARIAN_

ROBOT_NOT_READY

Requested action can

not be performed;

robot is busy or in use

Microcode

100%

2419

FSC_LIBRARIAN_

ILLEGAL_MAG_

INSERTED

Magazine 5 present in

6 drive, 7 magazine

configuration

Microcode

100%

241A

FSC_LIBRARIAN_NON_

HOMOGENOUS_STACK

Stack contains

modules configured

for different media to

stack-master

Microcode

100%

2500

FSC_SCSI_NO_

RESOURCE

SCSI task initialization

failed

Microcode

100%

2501

FSC_SCSI_BAD_

MESSAGE

SCSI task received a

bad message

Microcode

100%

2502

FSC_SCSI_QUEUE_FULL

SCSI queue full

Microcode

100%

2503

FSC_SCSI_NO_FAS366

FAS366 not detected

Servo/SCSI

100%

FSC

Name

Description

FRU Name

Confidence %