Quantum ATL M-Series User Manual
Page 134
Appendix B Fault Symptom Code (FSC) Dictionary
116
ATL M-Series User’s Guide
1000
FSC_FPGA_INIT_
STUCK_HI
FPGA INIT pin was
detected as being high
when it should have
been low
System
100%
1001
FSC_FPGA_INIT_NOT_
HI
FPGA INIT pin was
detected as being low
when it should have
been high
System
100%
1002
FSC_FPGA_DONE_
STUCK_HI
FPGA DONE pin was
detected as being high
when it should have
been low
System
100%
1003
FSC_FPGA_DONE_NOT_
HI
FPGA DONE pin was
detected as being low
when it should have
been high
System
100%
2000
FSC_DLT_INIT_FAILED
DLT initialization
failed
Microcode
100%
2001
FSC_DRIVE_TIMEOUT_1
Drive time out waiting
for status (drive 1)
Drive
100%
2002
FSC_DRIVE_TIMEOUT_2
Drive time out waiting
for status (drive 2)
Drive
100%
2003
FSC_DRIVE_TIMEOUT_3
Drive time out waiting
for status (drive 3)
Drive
100%
2004
FSC_DRIVE_TIMEOUT_4
Drive time out waiting
for status (drive 4)
Drive
100%
2005
FSC_DRIVE_TIMEOUT_5
Drive time out waiting
for status (drive 5)
Drive
100%
2006
FSC_DRIVE_TIMEOUT_6
Drive time out waiting
for status (drive 6)
Drive
100%
FSC
Name
Description
FRU Name
Confidence %