beautypg.com

Quantum ATL M-Series User Manual

Page 133

background image

Appendix B Fault Symptom Code (FSC) Dictionary

ATL M-Series User’s Guide

115

0014

FSC_BAD_MALLOC_

BLOCK_TRAILER

Heap consistency

check found

corruption

Microcode

100%

0015

FSC_WATCHDOG_
ERROR

An unexpected non-
maskable interrupt has

occurred

Microcode

100%

0016

FSC_MALLOC_

REQUEST_TOO_BIG

Size passed to malloc

too large

Microcode

100%

0017

FSC_CALLOC_

REQUEST_TOO_BIG

Size passed to calloc

too large

Microcode

100%

0018

FSC_REALLOC_

REQUEST_TOO_BIG

Size passed to realloc

too large

Microcode

100%

0019

FSC_EXCEPTION_3

Breakpoint instruction

executed

Microcode

100%

001A

FSC_EXCEPTION_1

Debug exception

occurred

Microcode

100%

001B

FSC_NULL_POINTER_

WRITE

Code attempted to

write to address 0

Microcode

100%

001C

FSC_EXECUTE_AT_0

Code attempted to

execute at address 0

Microcode

100%

001D

FSC_NULL_POINTER_

WRITE_NEAR

Code attempted to

write to address 0

Microcode

100%

001E

FSC_EXECUTE_AT_0_

NEAR

Code attempted to

execute at address 0

Microcode

100%

001F

FSC_UNSUPPORTED_

SYSTEM_BOARD

Old system boards are

no longer supported

Microcode

100%

0020

FSC_NO_OSTIMER_

INTERRUPT

OS timer interrupt

should have occurred,

but hasn't

Microcode

100%

FSC

Name

Description

FRU Name