Activity n2: testing the hardware, Normal mode error sequence, Table 4-3 . normal mode error led states – Nortel Networks 6300 User Manual
Page 94: Activity, Stat green, Attn amber, Traf green, Activity ne2: hardware failure, Table 4-3. normal mode error led states
Remote Annex 6300 Hardware Installation Guide
Chapter 4
Troubleshooting Procedures
4-6
Activity N2: Testing
the Hardware
During the power-up sequence, the Remote Annex 6300 runs a series
of self-test diagnostics. These diagnostics test internal hardware
functions. If a test fails, the ATTN and STAT LEDs flash and an error
message is displayed on the console port. The Ethernet LED (Link
LED) lights for a few seconds, then the TRAF LED flashes during the
power-up self-tests. After the self-tests complete, only the STAT and
Ethernet Link LED remain on.
Normal Mode Error Sequence
shows the state of the LEDs when an error occurs at various
stages of the start-up process. If the Remote Annex 6300 fails during
the hardware-test state (N2), the error condition is hardware failure
NE2. A description of possible causes and solutions for each error
condition is in the following paragraphs.
Table 4-3. Normal Mode Error LED States
Key:
●
On continuously.
✕
Off.
■
Flashing irregularly.
◆
Flashing regularly (about 1Hz).
Activity NE2:
Hardware Failure
The ROM diagnostics detected a Remote Annex 6300 hardware
problem requiring service; call Technical Support.
Activity
STAT
Green
ATTN
Amber
TRAF
Green
NE2: Hardware Failure
◆
◆
✕
NE5: Booted wrong image
●
◆
●