beautypg.com

Line/trunk (lt) cards, Table 4-3 – NEC NEAX 2000 IPS User Manual

Page 55

background image

Chapter 4 Circuit Cards

Line/Trunk (LT) Cards

NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1

Page 45

Line/Trunk (LT) Cards

Table 4-3

shows a summary of the Line/Trunk (LT) cards for NEAX 2000 IPS. The LT cards may be installed in

Slot 00 to 11 of PIM 0-7, with the following conditions:

Maximum 64 ports per PIM

Table 4-3 Line/Trunk (LT) Cards

ABBR.

NAME CODE

PART

NUMBER

PORT

REMARKS

IP PAD

SPN-32IPLA IP PAD

SC-3013 IXS IP PAD PROG-A1

151227

32

IP Interface Card
• For IP PAD
• Maximum of two without FP system
• Maximum of two per FP system
• Maximum of eight per system

SPN-16VCTA IP PAD

IP-TRK BUS CA
SP-3636 VCTA VC PROG-A

151226

0

16-channel CODEC Card
• For IP PAD
• Maximum of two per 32IPLA card
• Minimum of one 16VCT is required per

32IPLA.

LC

PN-8LCAA

150114

8

8-line Analog Line Circuit
• Message Waiting Control: Eight circuits
• Momentary Open: Eight circuits
• Loop Resistance: Maximum 600

including telephone set

PN-4LCD-A

150216

4

4-line Analog Line Circuit
• Message Waiting Lamp Control
• Momentary Open: One circuit
• Loop Resistance: Maximum 600

including telephone set

PN-4LLCB

151220

4

4-line Long Line Circuit
• Works in either mode:
• Long Line Station
• Caller ID
• Loop Resistance: Maximum 2,500

including telephone set

• PZ-PW122 is required.