BUS Cable Connection between IP-PAD and VCT Cards
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 21
BUS Cable Connection between IP-PAD and VCT Cards
Connect the VCTB/VCTA connector on the IP-PAD card and the VCT1A/VCT0A
connector on the VCT card by the IPTRK BUS CA, as shown below.
When two VCT cards are mounted, connect the VCT1B/VCT0B connector on the
VCT card with the VCT1A/VCT0A connector on the next VCT card, one after
another.
Figure 2-11 IP-PAD BUS Cable Connection
Note:
The IPTRK BUS CA consists of a set of three identical cables. Make sure to
connect the IP-PAD and VCT cards by using this set of cables, confirming that
connecting location of each cable must be matched in both IP-PAD and VCT
cards, as shown in
.
IPTRK BUS CA
[0.33 ft. (0.1 m)]
Note
To Dterm IP via LAN
To Internet/Intranet via LAN
IPTRK BUS CA
[0.33 ft. (0.1 m)]