Scheduled Logging Parameters

The phone can be configured to schedule certain advanced logging tasks on a

periodic basis. These attributes should be set in consultation with Polycom
Technical Support. Each scheduled log task is controlled by a unique attribute

set starting with log.sched.x where x identifies the task.

log.render.file.size

positive
integer, 1 to
179.5

16

Maximum local application log file
size in Kbytes. When this size is
exceeded, the file is uploaded to
the boot server and the local copy
is erased.

log.render.file.upload.period

positive
integer

172800

Time in seconds between log file
uploads to the boot server.

Note: The log file will not be
uploaded if no new events have
been logged since the last upload
.

log.render.file.upload.append

0, 1

1

If set to 1, use append mode when
uploading log files to server.

Note: HTTP and TFTP don’t
support append mode unless the
server is set up for this
.

log.render.file.upload.append.sizeLimit

positive
integer

512

Maximum log file size on boot
server in Kbytes.

log.render.file.upload.append.limitMode

delete, stop

delete

Behavior when server log file has
reached its limit.

delete=delete file and start over

stop=stop appending to file

Attribute

Permitted
Values

Default

Interpretation

Attribute

Permitted
Values

Interpretation

log.sched.x.name

alphanumeric
string

Name of an internal system command to be periodically executed.
To be supplied by Polycom.

log.sched.x.level

0-5

Event class to assign to the log events generated by this command.
This needs to be the same or higher than log.level.change.slog for
these events to appear in the log.

log.sched.x.period

positive
integer

Seconds between each command execution. 0=run once