beautypg.com

Master configuration files, R to, Information, refer to – Polycom SOUNDPOINT SIP 2.2.0 User Manual

Page 114

background image

Administrator’s Guide SoundPoint IP / SoundStation IP

A - 2

Master Configuration Files

The master configuration files can be one of:

Specified master configuration file—The master configuration file can be

explicitly specified in the boot server address, for example,

http://usr:pwd@server/dir/example1.cfg. The filename must end with

.cfg and be at least five characters long. If this file cannot be downloaded,

the phone will search for the per-phone master configuration file

(described next).

Per-phone master configuration file—If per-phone customization is

required, the file should be named .cfg, where

Ethernet address is the MAC address of the phone in question. For A-F

hexadecimal digits, use upper or lower case, for example,

0004f200106c.cfg. The Ethernet address can be viewed using the About

soft key during the auto-restart countdown of the bootROM or through

the Menu > Status > Platform > Phone menu in the application. It is also

printed on a label on the back of the phone. If this file cannot be

downloaded, the phone will search for the default master configuration

file (described next).

Default master configuration file—For systems in which the configuration

is identical for all phones (no per-phone .cfg files), the

default master configuration file may be used to set the configuration for

all phones. The file named 000000000000.cfg (<12 zeros>.cfg) is the default

master configuration file and it is recommended that one be present on the

boot server. If a phone does not find its own .cfg file,

it will use this one, and establish a baseline configuration. This file is part

of the standard Polycom distribution of configuration files. It should be

used as the template for the .cfg files.
The default master configuration file, 000000000000.cfg, is shown below:

< APPLICATION APP_FILE_PATH=”sip.ld”

CONFIG_FILES=”phone1.cfg, sip.cfg” MISC_FILES=””

LOG FILE DIRECTORY=”” OVERRIDES_DIRECTORY=””

CONTACTS_DIRECTORY=”” LICENSE_DIRECTORY=””/>

Master configuration files contain six XML attributes:

APP_FILE_PATH—The path name of the application executable. It can

have a maximum length of 255 characters. This can be a URL with its own

protocol, user name and password, for example

http://usr:pwd@server/dir/sip.ld.