Cli monitoring parameters, Parameter tables, Cli monitoring parameters parameter tables – Proxim ORINOCO AP-2000 User Manual
Page 156: Set vlan/ssid parameters, Using the command line interface (cli)
156
Using the Command Line Interface (CLI)
Set Hardware Configuration Reset Parameters
The Hardware Configuration Reset commands allows you to enable or disable the hardware reset functionality and to
change the password to be used for configuration reset during boot up.
To disable hardware configuration reset, enter:
[Device-Name]>set hwconfigresetstatus disable
To enable hardware configuration reset, enter:
[Device-Name]>set hwconfigresetstatus enable
To define the Configuration Reset Password to be used for configuration reset during boot up, enter the following
command
[Device-Name]>set configresetpasswd
It is important to safely store the configuration reset password. If a user forgets the configuration reset password, the
user will be unable to reset the AP to factory default configuration if the AP becomes inaccessible and the hardware
configuration reset functionality is disable.
Set VLAN/SSID Parameters
Enable VLAN Management
[Device-Name]>set vlanstatus enable
[Device-Name]>set vlanmgmtid <-1-4094>
[Device-Name]>show wifssidtbl (to review your settings)
[Device-Name]>reboot 0
Disable VLAN Management
[Device-Name]>set vlanstatus disable or 2
[Device-Name]>set vlanmgmtid 0
[Device-Name]>reboot 0
CLI Monitoring Parameters
Using the show command with the following table parameters will display operating statistics for the AP (these are the
same statistics that are described in
for the HTTP Web interface).
–
staticmp: Displays the ICMP Statistics.
–
statarptbl: Displays the IP ARP Table Statistics.
–
statbridgetbl: Displays the Learn Table.
–
statiapp: Displays the IAPP Statistics.
–
statradius: Displays the RADIUS Authentication Statistics.
–
statif: Displays information and statistics about the Ethernet and wireless interfaces.
–
stat802.11: Displays additional statistics for the wireless interfaces.
–
statethernet: Displays additional statistics for the Ethernet interface.
–
statmss: Displays station statistics and Wireless Distribution System links.
Parameter Tables
Objects contain groups that contain both parameters and parameter tables. Use the following Tables to configure the
Access Point. Columns used on the tables include:
— Name - Parameter, Group, or Table Name
— Type - Data type
— Values - Value range, and default value, if any
— Access = access type, R = Read Only (show), RW = Read-Write (can be “set”), W = Write Only
— CLI Parameter - Parameter name as used in the Access Point