Configuration Options

4-60

9820-A2-GB20-20

June 2000

Table 4-19.

Modem Port Options (2 of 3)

Port Access Level

Possible Settings: Level-1, Level-2, Level-3
Default Setting: Level-1

Specifies level of user access privilege for the asynchronous terminal interface
accessed through the Modem port. If a login is required for the port, the effective access
level is determined by the user’s access level. When a login is

not required, the effective

access level is determined by this option.

NOTE:

The effective access level is always the lowest one assigned to either the
port or the user. For example, if the Port Access Level assigned is Level-2,
but the User Access Level is Level-3, then only level-3 access will be
permitted for the port.

Display Conditions – This option only appears when Port Use is set to Terminal.

Level-1 – Allows full access and control of the device including monitoring, diagnostics,
and configuration. The user can add, change, and display configuration options, and
perform device testing.

CAUTION: Before changing the communication port’s access level to Level-2 or 3,

make sure that the Telnet Session Access Level is set top Level-1 and at
least one Login ID is set to Level-1. Otherwise, access will be lost. If this
occurs, you must reset the unit to the factory defaults and begin the
configuration process again.

Level-2 – Allows limited access and control of the device. The user can monitor and
perform diagnostics, display status and configuration option information.

Level-3 – Allows limited access with monitoring control only. The user can monitor and
display status and configuration screens only.

Inactivity Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether a user session is disconnected after a specified time of inactivity
(no keyboard activity).

Display Conditions – This option only appears when Port Use is set to Terminal.

Enable – Disconnects user session after the specified time of inactivity.

Disable – Does not disconnect user session.

Disconnect Time (Minutes)

Possible Settings: 1 – 60
Default Setting: 10

Specifies the number of minutes of inactivity that can elapse before the session is
disconnected.

Display Conditions – This option only appears when Port Use is set to Terminal.

1 – 60 – Sets the time from 1 to 60 minutes (inclusive).