beautypg.com

Paradyne 9820-2M User Manual

Page 192

background image

Setting Up NetScout Manager Plus for FrameSaver Devices

10-14

9820-A2-GB20-20

June 2000

"

Procedure

1. Open a terminal window and go to $NSHOME/usr.

2. Copy an example or interface-specific file to a new file that contains the user

history table number.

3. Open the new file using a text editor.

The variables in the file are listed with their OIDs (Object IDs). The frame
relay interface number 101016002 must replace @IFN, and the DLCI number
to be monitored must replace @DLCI.

Example: frCircuitSentFrames
Change “

1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI

to “

1.3.6.1.2.1.10.32.2.1.6.101016002.301

The only valid interface number for a FrameSaver 9820 model is 101016002.

4. Edit the new file, as needed.

Refer to

Creating .UDH Files and Using Custom History in the NetScout Manager

Plus User Guide for additional information.

See Appendix B,

SNMP MIBs and Traps, and RMON Alarm Default

, for OID

information for an interface.

This manual is related to the following products: