Dlci alarm defaults – paradyne area, B-19 – Paradyne 9820-2M User Manual

Page 235

background image

SNMP MIBs and Traps, and RMON Alarm Defaults

B-19

9820-A2-GB20-20

June 2000

DLCI Alarm Defaults – Paradyne Area

These alarms apply to all DLCIs on the network interface and can be created
during RMON initialization or when a DLCI is created. They are put into the
Paradyne alarm area.

Table B-12.

DLCI Alarm Defaults – Paradyne Area (1 of 2)

Item

Sample
Type

1

MIB/Tag/OID

2

Interval

Event
Type

Rising
Threshold
Default

Falling
Threshold
Default

DLCI Inactive
Seconds

D

MIB: pdn_FrExt.mib (E)

Tag: devFrExtDlciStsInactive-
Secs

OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.2.I.D

900 secs
(15 mins)

Rising

1

1

Missing Latency
Responses

D

MIB: pdn_FrExt.mib (E)

Tag: devFrExtDlciMissedSLVs

OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.23.I.D

900 secs
(15 mins)

Rising

5

5

Rx FECNs

D

MIB: FR DTE MIB
(RFC 2115)

Tag: frCircuitReceivedFECNs

OID: .1.3.6.1.2.1.10.32.2.1.
4.I.D

60 secs
(1 min)

Rising

1

1

Rx BECNs

D

MIB: FR DTE MIB
(RFC 2115)

Tag: frCircuitReceivedBECNs

OID: .1.3.6.1.2.1.10.32.2.1.
5.I.D

60 secs
(1 min)

Rising

1

1

Congested Seconds

D

MIB: pdn_FrExt.mib (E)

Tag: devFrExtDlciSts-
CongestedSecs

OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.6.I.D

60 secs
(1 min)

Rising

5

5

Frames Dropped by
Network

D

MIB: pdn_FrExt.mib (E)

Tag: devFrExtDlciNetDropFr

OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.20.I.D

60 secs
(1 min)

Rising

1

1