Paradyne 9820-2M User Manual
Page 124
Monitoring
6-14
9820-A2-GB20-20
June 2000
Table 6-9.
Device Messages (4 of 5)
Message
What To Do
What It Indicates
Not enough circuits
available
A new TS Access DLCI
was selected, but the
maximum number of
network DLCIs or
management PVCs has
already been created.
Delete a DLCI, then create the
new DLCI.
Note: This PVC has
been designated as
the TS Management
Link
The Management PVC you
displayed is defined as the
TS Management Link.
No action needed. The PVC
cannot be modified.
No VCIs available on
VPI
All virtual circuits for the
VPI have been assigned in
other DLCI records or
Management PVCs.
Select a different VPI.
Password Matching
Error – Re-enter
Password
Password entered in the
Re-enter Password field of
the Administer Logins
screen does not match
what was entered in the
Password field.
H
Try again.
H
Contact your system
administrator to verify your
password.
Permission Denied
(Seen at an FTP
terminal.)
A file transfer was
attempted, but the:
H
User did not have
Level 1 security.
H
See your system administrator
to get your security level
changed.
H
Wrong file was specified
when the put command
was entered.
H
Try again, entering the correct
file with the put command.
H
User attempted to
upload a program file
from the unit.
H
Enter the put command
instead of a get command;
you can only transfer files to
the unit, not from it.
Please Wait
Command takes longer
than 5 seconds.
Wait until message clears.
Resetting Device,
Please Wait ...
Yes (or y) was entered in
the
Reset COM Port usage
field of the System Paused
menu.
No action needed.