Configuration Options
4-39
9820-A2-GB20-20
June 2000
Table 4-11.
Management PVC Options (4 of 4)
Alternate Link
Possible Settings: Net1-FR1
Default Setting: Initially blank; no default.
Specifies the alternate frame relay interface to use for this management PVC if the
primary link has failed. The interface selected must have at least one DLCI (or DLCI
with EDLCI) defined, which is not part of a PVC connection or already assigned as a
management PVC.
Display Conditions – This option appears only for Model 9820-45M.
Net1-FR1 – Specifies that the network interface be used in the connection.
Alternate DLCI
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the alternate DLCI number used for the management PVC after the frame
relay interface is selected and the primary link has failed.
The DLCI must be defined for the link (i.e., has a DLCI record), and it must not be part
of a PVC connection or already assigned as a management PVC. For multiplexed
DLCIs, at least one EDLCI must be unconfigured for the DLCI.
Display Conditions – This option appears only for Model 9820-45M.
NOTES: – DLCI cannot be entered if the Link field is blank.
– Clearing the Link also clears the DLCI.
16 – 1007 – Specifies the DLCI number (inclusive).
Alternate EDLCI
Possible Settings: 0 – 62
Default Setting: Initially blank; no default.
Specifies the alternate EDLCI number used for a management PVC when a multiplexed
DLCI is selected and the primary link has failed. EDLCIs identify individual connections
within multiplexed DLCIs that are unique to those DLCIs.
Use a unique EDLCI to identify an individual connection within a multiplexed DLCI.
Use 0 to identify the primary EDLCI. Use 1 – 62 to identify secondary EDLCIs. Use the
primary EDLCI for customer data, which has a higher utilization rate than management
data, with slightly less line overhead.
Display Conditions – This option appears only for Model 9820-45M, and only if the
DLCI field references a multiplexed DLCI.
NOTE:
Clearing the DLCI or changing it to a standard DLCI suppresses EDLCI
field.
0 – 62 – Specifies the EDLCI number (inclusive).