beautypg.com

Paradyne 9820-2M User Manual

Page 39

background image

Configuration Options

4-3

9820-A2-GB20-20

June 2000

Configuring Using the Easy Install Screen
(Model 9820-45M)

The Easy Install screen provides direct access to the configuration options
required to establish communication and prepare for Auto-Configuration.

Main Menu

Easy Install

Table 4-1.

Easy Install Configuration Options (1 of 2)

Node IP Address

Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)

Specifies the IP address needed to access the node. Since an IP address is not bound
to a particular port, it can be used for remote access via a management PVC.

This address may be shared only among management PVCs.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the node, which can be
viewed or edited.

Clear – Fills the node IP address with zeros.

Node Subnet Mask

Possible Settings: 000.000.000.000 – 255.255.255.255, Clear
Default Setting: 000.000.000.000

Specifies the subnet mask needed to access the node. Since the subnet mask is not
bound to a particular port, it can be used for remote access via a management PVC.

000.000.000.000 – 255.255.255.255 – Shows the subnet mask for the node, which can
be viewed or edited.

Clear – Fills the node subnet mask with zeros. When the node’s subnet mask is
all zeros, the IP protocol creates a default subnet mask based upon the class of the
IP address: Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C:
255.255.255.000.

TS Access (Type)

Possible Settings: None, DLCI
Default Setting:

None

Specifies whether a DLCI is defined for troubleshooting by the service provider.

None – A troubleshooting DLCI is not defined.

DLCI – A troubleshooting DLCI is defined. Its value must be entered in the next field.

TS Access (DLCI)

Possible Settings: 16–1007
Default Setting:

blank

Specifies the DLCI on the network interface to be used for troubleshooting by the
service provider.

16 – 1007 – Specifies the DLCI.

Create a Dedicated Network Management Link

With the cursor on the Create a Dedicated Network Management Link field, press Enter.
When prompted, enter a DLCI for the link from 16 to 1007. The management link DLCI
is added or modified.