Health and Status Messages

The following table provides Health and Status messages that apply to the
FrameSaver unit.

Table 6-11.

Health and Status Messages (1 of 2)

Message

What It Indicates

Auto-Configuration Active

Auto-Configuration feature is active, which allows
automatic configuration and cross-connection of
DLCIs as they are reported by the network LMI.

Back-to-Back Mode Active

The operating mode has been configured for
back-to-back operation (

Main Menu

Control

Change Operating Mode).

The FrameSaver unit can be connected to another
FrameSaver unit without a frame relay switch
between them.

This feature is useful for product demonstrations
or for a point-to-point configuration using a leased
line.

Backup Active

(Model 9820-45M) A backup has been established
and data is flowing over an alternate DLCI.

Clock Out of Range at Network 1

A valid network data port rate cannot be detected
because the:

H

Unit is trying to detect a valid port rate.

H

Rate detected is greater than the highest port
rate supported by the unit.

– FrameSaver SLV 9820 rates:

56/64 or 128 kbps in 56 or 64 kbps
increments

– FrameSaver SLV 9820-2M rates:

64 – 2048 kbps in 64 kbps increments

– FrameSaver SLV 9820-8M rates:

1024 – 8192 kbps in 8 kbps increments

– FrameSaver SLV 9820-45M rates:

1024 – 44210 kbps in 8 kbps increments

CTS down to Port-1 Device

(Models 9820, 9820-2M, 9820-8M) The user data
port CTS control lead on the FrameSaver unit is
off.

DLCI

nnnn Down,

frame relay link

1, 2

The DLCI for the specified frame relay link is down.

DTR Down from Port-1 Device

The DTR control lead from the device connected to
the user data port is deasserted.

1

nnnn indicates a DLCI number of 16 through 1007.

2

frame relay link is one of the following:

– Net1-FR1. The frame relay link specified for the network interface, Network 1.

– Port-1. The frame relay link associated with the user data port.