Input/output signal settings, 1-1. setting the frame synchronizer – Panasonic AV-HS450N User Manual
Page 97
97
4. Input/output signal settings
4-1-1. Setting the frame synchronizer
The frame synchronizer can be set to On or Off for each input.
The DVI input (option) frame synchronizer is permanently On. It cannot be set from On to Off or vice versa.
Press the [INPUT] button to light its indicator and display the INPUT menu.
Refer to “2-1-5. LCD menu area”.
Turn [F1] to display the INPUT XX sub menu.
(X: IN1 to IN16, A1, A2, B1 or B2)
The input used to set the frame synchronizer function is selected for X.
Turn [F2] to display the third menu of FS.
display>
INPUT XX|FS |FS |Mode↓ |CC
| 1/13 | On|
Normal| Off
Off DbyD
UC
Auto
On
Turn [F3] to set On or Off for the frame synchronizer using the FS item.
If the output signal phase is set to 0H, Off cannot be selected as the FS item setting.
AVDL function is active while the frame synchronizer function is set to Off.
The AVDL function automatically adjusts the input image signal phase to the horizontal synchronization
reference signal phase.
For details, refer to “4-7. Adjusting the output signal phase”.