Replacement, English – Panasonic TQBJ0350 User Manual
Page 80
Replacement
80
- ENGLISH
Maintenance
Use a Phillips screwdriver to loosen
4 )
the “Lamp unit cover fixing screw”
(3 screws) for the lamp unit to be
replaced until the screws turn freely.
Hold the “Handle” of the “Lamp unit”
and gently pull the lamp unit out from
the projector.
Replace the new LAMP unit in correct
5 )
direction.
Use a Phillips screwdriver to securely
6 )
tighten the 2 “Lamp Unit cover fixing
screw” for lamp unit.
Note
When the lamp unit is replaced, the duration of usage
z
time will be reset to “0”.
Open the “Exhaust Fan” as illustrated,
7 )
and remove the “Air Filter” from “Air
filter housing".
Mount a new “Air Filter” in the
8 )
“Air Filter housing”, and close the
“Exhaust Fan".
Close the “Exhaust Fan” cover in the
9 )
reverse procedure of Step (3). Then,
tighten and secure the “Exhaust
fan fixing screw” (1 piece) using a
Phillips-head screwdriver.
Mount the “Air Filter/Lamp Unit
10 )
cover", and retighten "Air Filter/Lamp
Unit cover fixing screw" (1 piece) of
this cover securely.
Handle
Lamp unit fixing screws
Lamp unit installation
guide
Groove for lamp unit
installation guide
Handle
Air filter
Air filter housing