beautypg.com

Replacement, English, Air filter – Panasonic TQBJ0350 User Manual

Page 79: Procedure of air filter/lamp unit replacement

background image

Replacement

ENGLISH -

79

Maintenance

AIR FILTER

J

Optional air filter (service part) is available from any Panasonic dealer.

When you replace the projector lamp, replace the air filter at the same time.

The replacement lamp unit (part number ET-LAD60A, 1 bulb unit) package contains one air filter (part number

ET-LAD60A), but the ET-LAD60AW lamp unit (part number ET-LAD60AW, 2 bulb units) package contains two

air filters (part number ET-LAD60AW).

Procedure of Air Filter/Lamp Unit replacement

J

Attention

When the projector is mounted in the ceiling, do not work directly under the projector or put your face close to the projector.

z

The lamp unit and the lamp unit cover must be attached correctly and securely. Failure to do so, the projector will not be

z

turned on for the protection circuit.

If the lamp unit is not installed smoothly, remove it and then install it again. If it is pushed in forcibly, its connector may be

z

broken.

Turn the main power OFF, following

1 )

the procedures described in

“Powering off the projector”

(

Æ

page 34), disconnect the power

plug from the AC power source, and

wait for one hour or more. Then check

that the lamp unit has cooled down.
Loosen a "Air Filter/Lamp Unit

2 )

cover fixing screw" (1 piece) using

a Phillips-head screwdriver, and

remove “Air Filter/Lamp Unit cover".

Loosen the “Exhaust fan fixing

3 )

screw” (1 piece) using a Phillips-head

screwdriver to make it free to rotate,

and open the “Exhaust Fan” cover as

shown in the figure.

Air Filter/Lamp Unit cover

Air Filter/Lamp Unit cover fixing screw

Exhaust fan fixing screw

Exhaust fan

This manual is related to the following products: