SYSTEM REPORTING CODES

✦ Refer to the System Reporting Codes table to

view/edit the reporting codes for the keypad
FIRE and EMERGENCY buttons and for each of
the three Control Panel conditions. The factory
settings are listed, along with a blank area to
write in the new installation values.

STEPS #261-266

Any value from 0-99 can be programmed for
each event using these steps (enter “0” to stop
an event from reporting).

FORCE ARMING REPORTING CODE

✦ The factory set reporting code for force arming is

“65” (Code 574 with Ademco).

STEP #258 Any value from 0-99 can be programmed for this

event using this step (0 = no report).

NOTE: For force arming reporting, force arming

reports must be enabled. See Page 41.

DURESS REPORTING CODE

✦ The factory set reporting code for Duress is “66”

(Code 121 with Ademco).

STEP #259 Any value from 0-99 can be programmed for this

event using this step (0 = no report).

NOTE: For duress code reporting a keypad duress

code must be programmed. See Page 34.

SYSTEM REPORTING CODES

STEP #

PROGRAMMING FUNCTION

POSSIBLE

4 BY 2 VALUES

FACTORY

4 BY 2 VALUES

ADEMCO VALUE

INSTALLATION

4 BY 2 VALUE

258

FORCE ARMING REPORT CODE

0 - 99

65

574

259

DURESS REPORT CODE

0 - 99

66

121

261

SYSTEM FIRE REPORT CODE

0 - 99

68

110

262

SYSTEM EMERGENCY REPORT CODE

0 - 99

69

120

263

SYSTEM TEST/CANCEL REPORT CODE

0 - 99

70

406

264

SYSTEM LOW BATTERY RESTORAL REPORT CODE

0 - 99

71

R302

265

SYSTEM LOW BATTERY CODE

0 - 99

73

E302

OPENING & CLOSING REPORTING CODES TABLE

USER CODE

4 x 2 CLOSING

(ARMING) CODE

4 x 2 OPENING

(DISARMING) CODE

ADEMCO CLOSING

(ARMING) CODE

ADEMCO OPENING

(DISARMING) CODE

MASTER USER CODE1

74

82

R401 C000

E401 C000

RESTRICTED USER CODE #1

75

83

R401 C001

E401 C001

RESTRICTED USER CODE #2

76

84

R401 C002

E401 C002

RESTRICTED USER CODE #3

77

85

R401 C003

E401 C003

RESTRICTED USER CODE #4

78

86

R401 C004

E401 C004

RESTRICTED USER CODE #5

79

87

R401 C005

E401 C005

PAGE ALERT USER CODE

(DIALS PAGE NUMBER ONLY, NO CODES REPORTED)

REMOTE/HARDWIRE ARM (SENSOR FCN. 9) & QUICK ARM

81

R407 C007

REMOTE/HARDWIRE DISARM (SENSOR FCN. 9)

89

E407 C007

PROGRAMMING
STEPS #261 - 266

ENTERS STEP NUMBER

0 - 99 FOR SYSTEM
REPORTING CODE

STORES VALUE - 1 BING

PROGRAMMING STEP #258

ENTERS STEP NUMBER

0 - 99 FOR FORCE ARMING
REPORTING CODE

STORES VALUE - 1 BING

PROGRAMMING STEP #259

ENTERS STEP NUMBER

0 - 99 FOR DURESS CODE

STORES VALUE - 1 BING

Opening & Closing Reporting Codes Table