beautypg.com

Linear DUAL 824 User Manual

Page 32

background image

30

CHANGING A SENSORS SUPERVISION

✦ When a wireless sensor is programmed, the

Control Panel automatically sets it to supervised
or non-supervised. The hardwire loops are always
supervised for end-of-line resistor termination.

✦ The Control Panel expects hourly status

transmissions from any wireless sensor
programmed as supervised.

✦ Any wireless sensor can be programmed as

supervised or non-supervised using this process.

NOTE: Don't program a wireless sensor that

doesn't send status transmissions as supervised.

CHANGING A SENSORS RESTORE REQUIREMENTS

✦ When a wireless sensor is programmed, the

Control Panel automatically recognizes it as
manual or automatic restoring. The hardwired
loops are always manual restoring.

✦ The Control Panel expects restoral signals from any

wireless sensor programmed as manual restore.

✦ Any wireless sensor can be programmed as

manual or automatic restore using this process.

NOTE: Don't program a wireless sensor that doesn't

send restoral transmissions as manual restore.

ENTRY DELAY TIME

✦ The factory-set Entry Delay time is 30 seconds.

STEP #25 The Entry Delay time can be adjusted from 20 to

255 seconds using this step. Write the new Entry
Delay time in the User's Guide.

NOTE: Don't make the Entry Delay too short. The

user may not have enough time to disarm the
system before an alarm.

EXIT DELAY TIME

✦ The factory-set Exit Delay time is 60 seconds.

STEP #26 The Exit Delay time can be adjusted from 20 to

255 seconds using this step. Write the new Exit
Delay time in the User's Guide.

BURGLARY SIREN TIME

✦ The factory-set burglary siren time is fi ve minutes

(UL installation maximum).

STEP #30 The burglary siren time can be adjusted from one

to 30 minutes using this step.

EMERGENCY SIREN TIME

✦ The factory-set emergency siren time is fi ve

minutes (UL installation maximum).

STEP #31 The emergency siren time can be adjusted from

one to 30 minutes using this step.

NUMBER OF
SENSOR
TO CHANGE

SENSOR INDICATOR
FLASHES

ENTERS SENSOR NUMBER

18 FOR MANUAL RESTORE
19 FOR AUTO RESTORE

STORES CHANGE

1 BING AND SENSOR
INDICATOR LIT

NUMBER OF
SENSOR
TO CHANGE

SENSOR INDICATOR
FLASHES

ENTERS SENSOR NUMBER

16 FOR NON-SUPERVISED
17 FOR SUPERVISED

STORES CHANGE

1 BING AND SENSOR
INDICATOR LIT

PROGRAMMING STEP #25

ENTERS STEP NUMBER

TIME IN SECONDS 20 - 255

STORES VALUE - 1 BING

PROGRAMMING STEP #26

ENTERS STEP NUMBER

TIME IN SECONDS 20 - 255

STORES VALUE - 1 BING

PROGRAMMING STEP #30

ENTERS STEP NUMBER

TIME IN MINUTES 1 - 30

STORES VALUE - 1 BING

PROGRAMMING STEP #31

ENTERS STEP NUMBER

TIME IN MINUTES 1 - 30

STORES VALUE - 1 BING