beautypg.com

Linear DUAL 824 User Manual

Page 37

background image

35

ADDING ADDITIONAL USER CODES

✦ The Control Panel can be programmed with fi ve

restricted user codes and one page alert user code.

✦ The restricted user codes operate the system as

usual, but cannot access Setup Mode.

✦ The restricted user codes can access a special

Code Mode that can be used to change or
remove any of the fi ve restricted user codes, the
page alert user code, or the duress code.

✦ The page alert user code dials the supervisory

number (programmed for a pager) when it is
used to arm or disarm the system.

✦ A restricted user code is appropriate to give any

user that should be restricted from programming
the Control Panel.

NOTE: For maximum security, a 3-5 digit code is

recommended.

WARNING: NEVER PROGRAM ANY RESTRICTED

USER CODE THE SAME AS THE MASTER USER CODE!

STEPS #93-98

Create any additional user codes using these

steps then log the codes in the boxes to the right.

REMOVING ADDITIONAL USER CODES

STEPS #93-98 Any additional user code can be removed

from the Control Panel by entering the
appropriate step number and pressing TEST.

✦ Because access to programming would be

impossible without a master user code, it cannot be
removed using these steps.

The master user code

can be changed using programming STEP #99.

NOTE: The master user code can be set to the

factory default using the Control Panel master
reset programming step, although all other system
programming will be reset to factory values and all
sensors programmed will be erased.

CONTROL PANEL MASTER RESET

✦ Master resetting the Control Panel will set all of the

programming options back to the factory values.
The master user code will be reset to 1234.

CAUTION: Master resetting the Control Panel will erase

the user codes and remove all programmed sensors.
All Control Panel and communicator programming
values will be reset to the factory defaults.

1.

Start with the system in Test Mode (Setup Mode

cannot be reached from any other mode).

2.

From Test Mode, enter the master user code then

press TEST.

A “Gong” and fi ve “Beeps” will sound, signaling that the

system is in Setup Mode.

3.

Enter programming STEP #999 then press TEST.

4.

Enter 999 again then press TEST again.

A “Bing” will sound to indicate the beginning of the reset

process. This process will take up to 10 seconds while
the memory is being reset.

✦ The system will revert to the fi rst time power-

up condition and the new master user code
will be 1234. Go to the “Basic Control Panel
Programming” section of this manual to begin re-
programming the system.

PROGRAMMING STEP #93-98

ENTERS STEP NUMBER

1-5 DIGIT ADDITIONAL
USER CODE
(3-5 DIGITS RECOMMENDED)

STORES CODE - 1 BING

PROGRAMMING STEP #93-98

REMOVES CODE - 1 BING

93 = RESTRICTED CODE 1
94 = RESTRICTED CODE 2
95 = RESTRICTED CODE 3
96 = RESTRICTED CODE 4
97 = RESTRICTED CODE 5

98 = PAGE ALERT USER CODE

ENTER FOR STEP #

MASTER USER CODE

ENTERS TEST MODE
1 GONG & 5 BEEPS

STEP #999
FOR MASTER
RESET

ENTER 999 TO OK
THE MASTER RESET

START IN TEST

DONE

USE THESE EXACT
KEYSTROKES
TO PERFORM A
MASTER RESET

ENTERS STEP NUMBER

PRESS TEST, 1 BING SOUNDS,
WAIT ABOUT 10 SECONDS

STEP

CODE FUNCTION

CODE ENTERED

STEP #93

RESTRICTED USER CODE #1

STEP #94

RESTRICTED USER CODE #2

STEP #95

RESTRICTED USER CODE #3

STEP #96

RESTRICTED USER CODE #4

STEP #97

RESTRICTED USER CODE #5

STEP #98

PAGE ALERT USER CODE