beautypg.com

Linear DUAL 824 User Manual

Page 36

background image

34

AUTOMATION OUTPUT WHILE ARMED

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

key, or when it's triggered with a two-button

remote control.

STEP #73 The Control Panel can be programmed to

activate the Automation Output when the system
is armed as well as when normally triggered
using this step.

AUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

key, or when it's triggered with a two-button

remote control.

STEP #74 The Control Panel can be programmed to

activate the Automation Output during the exit
and Entry Delays as well as when normally
triggered using this step.

AUTOMATION OUTPUT POLARITY

✦ The factory setting causes the Control Panel's

Automation Output to provide a current limited
voltage source when activated.

STEP #75 The Control Panel can be programmed so the

Automation Output provides a current limited
voltage source when deactivated using this step.

REMOTE ACCESS PASSWORD

✦ This password is used to gain access to the Control

Panel when using the RA-2400 remote access
software. The password must be 6-digits long.

STEP #87 Use this step to enter a new remote access

password then log the password in the box
below.

DURESS CODE

✦ The duress code will disarm the system, without

any special indications or sounds, but will send
the programmed duress code to the Central
Station. The code should be two or more digits
different than any user code

STEP #92 Use this step to enter the duress code then log

the code in the box below.

MASTER USER CODE

✦ The master user code is 1234 when power is fi rst

applied to the Control Panel.

✦ The master user code can be changed to any

1-5 digit code. Only the master user can access
Setup Mode, restricted users cannot.

NOTE: For maximum security, a 3-5 digit code is

recommended.

STEP #99 Use this step to enter the new master user code

then log the code in the box below.

PROGRAMMING STEP #73

ENTERS STEP NUMBER

0 FOR STANDARD TRIGGER
1 FOR OUTPUT WHEN ARMED

STORES VALUE - 1 BING

PROGRAMMING STEP #74

ENTERS STEP NUMBER

0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING
EXIT/ENTRY DELAYS

STORES VALUE - 1 BING

PROGRAMMING STEP #75

ENTERS STEP NUMBER

0 FOR VOLTAGE WHEN OFF
1 FOR VOLTAGE WHEN ON

STORES VALUE - 1 BING

PROGRAMMING STEP #87

ENTERS STEP NUMBER

6-DIGIT REMOTE
ACCESS PASSWORD

STORES PASSWORD - 1 BING

REMOTE ACCESS PASSWORD:

PROGRAMMING STEP #92

ENTERS STEP NUMBER

1-5 DIGIT DURESS CODE
(3-5 DIGITS RECOMMENDED)

STORES CODE - 1 BING

DURESS CODE:

MASTER USER CODE:

PROGRAMMING STEP #99

ENTERS STEP NUMBER

1-5 DIGIT MASTER CODE
(3-5 DIGITS RECOMMENDED)

STORES CODE - 1 BING