AUTOMATION OUTPUT MODE DURING ALARM

✦ The factory setting causes the Automation

Output to fl ash if it is programmed to activate
during or after an alarm.

NOTE: For the Automation Output to activate

during or after an alarm, that function must be
enabled with Programming Step 71 or 72.

STEP #68 The output can be programmed to be a steady

output using this step.

AUTOMATION ACTIVATION TONE

✦ The factory setting causes the keypad(s) to

sound a “Bing” when the Automation Output is
activated by pressing the

key, or when it's

triggered with a two-button remote control.

STEP #69 This sound can be silenced using this step.

REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP

✦ When arming with the portable remote control

or with a hardwired loop programmed as arm/
disarm (sensor Function #9), the factory setting
causes the keypad(s) to “chirp” once when
armed, twice when disarmed, and three times
when arming with sensors bypassed.

STEP #70 These chirps can be silenced using this step.

NOTE: If these chirps are silenced, it is

recommended to program the Automation Output
to be active when the system is armed, so a light
can be triggered displaying the arming status of
the system.

AUTOMATION OUTPUT ON DURING AND AFTER ALARM

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

key, or when it's triggered with a two-button

remote control.

STEP #71 The Control Panel can be programmed to

activate the Automation Output during and after
any alarms as well as when normally triggered
using this step.

NOTE: The output will continue until the fl ashing

sensor status lights are cleared.

AUTOMATION OUTPUT ON DURING ALARM

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

key, or when it's triggered with a two-button

remote control.

STEP #72 The Control Panel can be programmed to

activate the Automation Output during alarms as
well as when normally triggered using this step.

NOTE: The Automation Output can be programmed

to fl ash or be steady during alarm, see
Programming Step 68.

PROGRAMMING STEP #68

ENTERS STEP NUMBER

0 FOR FLASHING OUTPUT
1 FOR STEADY OUTPUT

STORES VALUE - 1 BING

PROGRAMMING STEP #69

ENTERS STEP NUMBER

0 FOR BING TONE OFF
1 FOR BING TONE ON

STORES VALUE - 1 BING

PROGRAMMING STEP #70

ENTERS STEP NUMBER

0 FOR CHIRPS OFF
1 FOR CHIRPS ON

STORES VALUE - 1 BING

PROGRAMMING STEP #71

ENTERS STEP NUMBER

0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING &
AFTER ALARM

STORES VALUE - 1 BING

PROGRAMMING STEP #72

ENTERS STEP NUMBER

0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING ALARM

STORES VALUE - 1 BING