beautypg.com

Advanced programming – Linear DUAL 824 User Manual

Page 31

background image

29

✦ To perform any of the advanced programming

steps, the system must be in the Setup Mode.

✦ Each programming function is performed with

similar keystrokes. After the system is in Setup
Mode, enter the programming step or sensor
number and press HOME, then enter the new
value and press AWAY. For reference, follow the
fi gures next to the programming steps.

If the new value is accepted, a “bing” will sound. If the

new value is not accepted, a “double buzz” will sound.

CONTROL PANEL PROGRAMMING OPTIONS

STEP #

PROGRAMMING FUNCTIONS

POSSIBLE VALUES

FACTORY VALUE

INSTALLATION VALUE

25

ENTRY DELAY

20-255 SECONDS

30

26

EXIT DELAY

20-255 SECONDS

60

30

BURGLARY SIREN TIME

1-30 MINUTES

5

31

EMERGENCY SIREN TIME

1-30 MINUTES

5

32

FIRE SIREN TIME

1-30 MINUTES

5

40

AUTOMATION OUTPUT TIME

0-2500 SECONDS (0 = TOGGLE ON/OFF)

0

50

REMOTE ARMING MODE

2 = HOME MODE; 3 = AWAY MODE

3

51

REMOTE DISARMING MODE

0 = OFF MODE; 1 = CHIME MODE

0

61

ENTRY DELAY BEEPS

0 = OFF; 1 = ON

1

62

EXIT DELAY BEEPS

0 = OFF; 1 = ON

1

63

SILENT BURGLARY ALARM

0 = AUDIBLE; 1 = SILENT

0

64

SILENT EMERGENCY ALARM

0 = AUDIBLE; 1 = SILENT

0

65

QUICK ARMING

0 = OFF; 1 = ON

1

66

AUTO RESTORE

0 = OFF; 1 = ON

1

67

AUTO BYPASS

0 = OFF; 1 = ON

0

68

AUTOMATION MODE DURING ALARM

0 = FLASH (ENABLED BY FUNCTION 72)
1 = STEADY (ENABLED BY FUNCTION 72)

0

69

AUTOMATION BING TOME

0 = NO BINGS
1 = BINGS

1

70

REMOTE ARM/DISARM CHIRP

0 = NO CHIRPS
1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED)

1

71

AUTOMATION FLASHES AFTER ALARM

0 = STANDARD
1 = FLASHING AFTER ALARM

0

72

AUTOMATION ACTIVE DURING ALARM

0 = STANDARD
1 = AUTOMATION ACTIVE DURING ALARM
(FLASH OR STEADY PROGRAMMED BY FUNCTION 68)

0

73

AUTOMATION ON WHILE ARMED

0 = STANDARD
1 = ON WHILE ARMED

0

74

AUTOMATION ON DURING EXIT/ENTRY

0 = STANDARD
1 = ON DURING EXIT/ENTRY DELAY

0

75

AUTOMATION POLARITY

0 = + WHEN OFF; 1 = + WHEN ON

1

87

REMOTE ACCESS PASSWORD

6 DIGITS

987654

92

DURESS CODE

1-5 DIGITS

REMOVED

93

RESTRICTED USER CODE #1

1-5 DIGITS

REMOVED

94

RESTRICTED USER CODE #2

1-5 DIGITS

REMOVED

95

RESTRICTED USER CODE #3

1-5 DIGITS

REMOVED

96

RESTRICTED USER CODE #4

1-5 DIGITS

REMOVED

97

RESTRICTED USER CODE #5

1-5 DIGITS

REMOVED

98

PAGE ALERT USER CODE

1-5 DIGITS

REMOVED

99

MASTER USER CODE

1-5 DIGITS

1234

SETUP MODE

1. Start with the system in Test Mode (Setup Mode

cannot be reached from any other mode).

2. From Test Mode, enter the master user code then

press TEST.

NOTE: Only the master user code can be used to

put the system into the Setup Mode. The restricted
user codes cannot access Setup Mode, only Code
Mode.

A “Gong” and fi ve “Beeps” will sound, signaling that the

system is in Setup Mode.

3. After programming changes are complete, press

the OFF key for three seconds to exit Setup
Mode.

NOTE: If the system is left unattended in Setup

Mode, it will automatically switch back to Off Mode
after three minutes.

13. ADVANCED PROGRAMMING

ENTERS PROGRAM STEP OR
SENSOR NUMBER TO MODIFY

STORES NEW VALUE

Control Panel Programming Table