Linear DF-16/EC User Manual
Df-54/ec, Motion detector, Emergency
DF-54/EC
MOTION
DETECTOR
For Use with DF-16/EC
Security Console
Installation
Instructions
1. MOTION DETECTOR DETAIL
2. TYPICAL INSTALLATION
3. MOTION DETECTION PATTERN
4. CONNECT BATTERY
5. MOUNT MOTION DETECTOR BASE
6. PROGRAM DETECTOR INTO CONSOLE
7. WALK TEST MOTION DETECTOR
8. ALARM TEST MOTION DETECTOR
9. REPLACING MOTION DETECTOR BATTERY
10. IMPORTANT DETECTOR INFORMATION
1.
I
NTERNATIONAL WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months.
The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale
customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does
not warrant this product to consumers. Consumers should inquire from their selling dealer as to
the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of
Linear Corporation for consequential damages arising out of or in connection with use or
performance of this product or other indirect damages with respect to loss of property,
revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties,
including implied warranties for merchantability and implied warranties for fi tness, are valid only until
Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of
all other warranties express or implied. For warranty service on Linear equipment return product,
at sender’s expense to:
Linear Hong Kong 19/F Hounor Industrial Centre, 6 Sun Yip Street Chai Wan, Hong Kong
Attention: Repairs Department
REPAIRS POLICY
Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by
the effects of lightning, water, fi re, or other abnormal happenings.Customer’s equipment sent in for repair
may be repaired or replaced with new or remanufactured equipment at Linear’s discretion.The customer
is always responsible for shipping and handling charges to the repairs facility. Linear will pay return
shipping and handling charges on “in warranty” products shipped back to the customer. The customer will
be billed for the return shipping and handling charges on “out of warranty” products.There will be a 50%
expedite fee for any express requests.The International Sales Manager must be notifi ed prior to the return
of product to Linear. All international returns must have an International Repair Authorization number
(IRA#). The number must be marked on all packages. Failure to do so will cause delays in processing.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless
signaling. However, there are some limitations which must be observed. The radios are required to comply with
local rules and regulations as radio devices. As such, they have limited transmitter power and therefore limited
range. A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio
signals that occur on or near their operating frequencies, regardless of code settings. Changes or modifi cations
to the device may void regulatory compliance. Infrequently used radio links should be tested regularly to protect
against undetected interference or fault. A general knowledge of radio and its vagaries should be gained prior to
acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
(760) 438-7000 • FAX (760) 438-7043
www.linearcorp.com
PRINTER’S INSTR
UCTIONS:
INSTR,INSTL,DF-54/EC - LINEAR P/N:
210948 B - INK:
BLA
CK - MA
TERIAL:
20 LB
. MEAD BOND - SIZE:
11.000”
X 8.500”
- SCALE:
1-1
WALK
TEST
BUTTON
MOTION
DETECTOR
LENS
CASE
LOCKING
SCREW
(ON BOTTOM)
MOTION
DETECTOR
DON'T POINT AT HEAT SOURCES
(HEATERS, ETC.), WINDOWS, OTHER
MOTION DETECTORS OR DOOR/WINDOW
TRANSMITTERS
BEDROOM
BATH
KITCHEN
FRONT
ROOM
CONSOLE
(FOR INDOOR
USE ONLY)
MOUNT
DETECTOR
SO THAT
INTRUDER
WILL CROSS
BEAMS
DETECTION
AREA
9 METERS
9 METERS
9 METERS
2-3 METERS
SIDE
VIEW
TOP
VIEW
MOTION
DETECTOR
IN CORNER
REMOVE
SCREW
AND OPEN
CASE
CONNECT 9-VOLT ALKALINE
BATTERY TO BATTERY CLIP
(PLUS SIDE UP)
NOTE:
WAIT 5 MINUTES AFTER
CONNECTING BATTERY
FOR DETECTOR
TO STABILIZE
PUNCH OUT REQUIRED HOLES
FOR SCREW MOUNTING
USE CENTER
HOLES FOR
WALL
MOUNTING
USE SIDE HOLES
FOR CORNER
MOUNTING
NOTE:
THE DETECTOR CAN
BE MOUNTED WITH
DOUBLE STICK TAPE,
MOUNT
DETECTOR
6-8 FEET
HIGH
MOUNTING THE DETECTOR
IN A CORNER IS PREFERRED
AFTER MOUNTING, SNAP
DETECTOR ONTO BASE
AND REPLACE CASE SCREW
1
ENTER YOUR
SECRET CODE
PRESS
LEARN
ENTER AN
UNUSED SENSOR
NUMBER
PUSH WALK
TEST BUTTON
TO SEND SIGNAL
FROM MOTION
DETECTOR
START IN
OFF MODE
HOLD OFF BUTTON
FOR 3 SECONDS WHEN
FINISHED TO EXIT
LEARN MODE
LEARN BUTTON
WALK
TEST
BUTTON
PUSH
WALK
TEST
BUTTON
WALK IN FRONT OF
UNIT WHILE WATCHING
RED LIGHT
UNIT WILL STAY IN
WALK TEST MODE
FOR 4 MINUTES AFTER
PRESSING WALK TEST
BUTTON THEN AUTOMATICALLY
RETURN TO "OPERATE" MODE
VERIFY THAT DETECTION
PATTERN COVERS DESIRED
AREA & THAT CONSOLE
STATUS INDICATOR LIGHTS
WHEN MOTION IS DETECTED
AFTER INITIAL SETUP,
WALK TEST UNIT YEARLY
NOTE:
EMERGENCY
EMERGENCY
PLACE CONSOLE IN OFF MODE
TO STOP SIREN, CHECK THAT SENSOR
STATUS LIGHT IS BLINKING.
AFTER FIVE MINUTES, WALKING
IN FRONT OF THE MOTION DETECTOR
SHOULD TRIGGER THE ALARM
PLACE CONSOLE IN THE
AWAY MODE
STAY OUT OF THE MOTION
DETECTION PATTERN AREA
FOR AT LEAST FIVE MINUTES
REMOVE
SCREW
AND OPEN
CASE
WHEN CONSOLE INDICATES A LOW BATTERY
FOR THIS SENSOR:
REPLACE THE BATTERY WITH
A FRESH 9-VOLT ALKALINE
BATTERY (PLUS SIDE UP)
USE ALKALINE
BATTERY ONLY
SNAP DETECTOR ONTO BASE
AND REPLACE CASE SCREW
WHEN FINISHED
NOTE: WAIT 5 MINUTES AFTER REPLACING
BATTERY FOR DETECTOR TO STABILIZE
1. The motion detector can only trigger the alarm
when the Console is in Away Mode.
2. Except in “Walk Test”, the detector must see no
motion for fi ve minutes before walking in front of
the unit will send an alarm signal.
3. When the Console is in Away Mode, the motion
detector will cause an instant alarm unless a
delayed perimeter door/window sensor is triggered
fi rst.
4. Operating temperature range:
+32° to +120° F (0° to +49° C)
R&TTE VAEE 27837, EMC, SFT, ETS
Linear Corporation declares that the apparatus
DF-54/EC complies with the essential requirements
and other relevant provisions of Directive 1995/5/EC.
Copyright © 2003 Linear Corporation
210948 B
BY