CALL LIMITER
✦ The factory setting for the call limiter is OFF.
This allows the communicator to report burglary
alarms, once for each sensor, as many times as
they are triggered.
STEP #101
The Control Panel can be programmed to only
allow fi ve burglary reports total per arming period
using this step.
✎ NOTE: Sensors programmed for 24-hour functions
(Emergency, Panic, Fire) always send a Central
Station report and always sound the local siren
regardless of the Call Limiter setting.
DIALING DELAY
✦ The factory setting will cause the communicator
to dial the Central Station instantly when an
alarm or supervisory event occurs.
STEP #103 The communicator can be programmed to
wait 30 seconds before dialing using this step.
This gives the user time to disarm the system
and prevent communications in the case of a
subscriber generated false alarm.
DIALING METHOD
✦ The factory setting causes the communicator to
dial using DTMF (dual-tone multi-frequency) tone
dialing.
STEP #104 The communicator can be programmed to use
pulse (rotary) dialing using this step. Use this
option if the telephone line in the installation
does not support tone dialing.
PROGRAMMING STEP #101
ENTERS STEP NUMBER
0 FOR OFF (UNLIMITED)
1 FOR ON (5 VIOLATIONS)
STORES VALUE - 1 BING
PROGRAMMING STEP #103
ENTERS STEP NUMBER
0 FOR NO DELAY
1 FOR 30 SECOND DELAY
STORES VALUE - 1 BING
PROGRAMMING STEP #104
ENTERS STEP NUMBER
0 FOR TONE DIALING
1 FOR PULSE DIALING
STORES VALUE - 1 BING