HARDWIRED LOOP WIRING

✦ The DUAL 824 supports up to eight normally

open/closed hardwired loops each with 2.2K
end-of-line resistor supervision.

✦ Each hardwired loop that is wired and

programmed uses one sensor location.

✦ Each hardwired loop can be programmed to any

sensor number.

✦ Each hardwired loop can be programmed as any

sensor type, including arm/disarm toggle.

✦ Four COM terminals are shared as loop returns

for the eight loops.

✦ Each hardwired loop has a 400 millisecond

response time.

NOTE: For UL installations, use UL Listed cable for

all hardwired loop wiring.

1. Route wiring from the Control Panel to each

hardwired switch contact, sensor, or device.
Route the wires through the wiring slot or
through a knockout for conduit wiring.

NOTE: Maximum recommended hardwired loop

length is 500 feet (250' out, and 250' back) for each
loop. Maximum loop resistance (excluding the EOL
resistor) is 100 ohms.

2. Connect the loop wires to LOOP # and COM

terminals. For powered devices connect power
wires to +12 VDC and any COM terminal.

3. On the sensor end, connect each normally

closed sensor in series with the loop wires.
Connect each normally open sensor in parallel
with the loop wires. See wiring fi gure.

4. After the last sensor on the loop, connect a 2.2K

end-of-line resistor across the loop.

NOTE: Before the hardwired loops will function,

they will need to be programmed. This will be
covered in the Basic Control Panel Programming
section of this manual.

ARM/DISARM KEY STATION WIRING

✦ Any of the hardwired loops can be used with a

momentary keyswitch to arm and disarm the
system.

1. Connect the loop as shown to the keyswitch and

end-of-line resistor.

2. Connect an LED indicator from the switch plate

to the H/A- and H/A+ terminals.

3. When programming the system, set the loop

sensor function to “Type 9, Arm/Disarm Toggle”
and set the Automation output to “Active while
Armed”.

RUN LOOP WIRING
BETWEEN THE CONTROL
PANEL AND THE REMOTE
HARDWIRED SENSORS

RUN 4-CONDUCTOR WIRE
TO POWERED DEVICES

RUN 2-CONDUCTOR WIRE
TO DEVICES NOT POWERED
FROM THE CONTROL PANEL

4-CONDUCTOR

FOR HARDWIRED

INFRAREDS

2-CONDUCTOR

FOR MAGNETIC

CONTACTS

LOOP

1

COM

LOOP

2

LOOP

3

COM

LOOP

4

LOOP

8

H/A

-

H/A

+

RLY

COM

RLY

N/C

RLY

N/O

COM

2.2K END-OF-LINE
RESISTOR FOR
EACH LOOP USED

NORMALLY CLOSED

SWITCHES (CONTACTS)

NORMALLY OPEN

SWITCHES (CONTACTS)

USE +12 VDC AND
ANY COM TERMINAL
TO POWER EXTERNAL
DEVICES (1 AMP MAX.)

MAIN TERMINAL BLOCK

+12

VDC

CONNECT EACH HARDWIRED
INPUT TO A LOOP AND COM
TERMINAL

FOR POWERED DEVICES, WIRE
POWER LEADS TO +12 VDC
AND ANY COMMON TERMINAL
(OBSERVE POLARITY)

LOOP

1

COM

LOOP

2

LOOP

3

COM

LOOP

4

LOOP

8

H/A

-

H/A

+

RLY

COM

RLY

N/C

RLY

N/O

COM

NORMALLY CLOSED,

SPRING RETURN, KEYSWITCH

470 OHM

KEYSTATION

2.2K OHM

LED

PROGRAM AUTOMATION
OUTPUT FOR "ACTIVE
WHILE ARMED"

LED WILL LIGHT
WHEN SYSTEM
IS ARMED

PROGRAM LOOP FOR
ARM/DISARM TOGGLE
(SENSOR TYPE 9)

MAIN TERMINAL BLOCK