beautypg.com

8 replacing the front i/o board, Replacing the front i/o board – Sun Microsystems Sun Fire X4100 User Manual

Page 91

background image

Chapter 3

Maintaining the Sun Fire X4100 Server

3-31

3.4.8

Replacing the Front I/O Board

Follow these steps to remove and replace the front I/O board.

Note –

This component is a FRU and should be replaced only by qualified service

technicians. Contact your Sun Service representative for assistance.

TABLE 3-8

lists the qualified part numbers for this component. These part numbers

are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:

http://www.sun.com/servers/entry/x4100/downloads.jsp

1. Power off the server as described in

Section 3.2.1, “Powering Off the Server” on

page 3-2

.

2. Disconnect any external cables from the front I/O board’s USB connectors.

3. If the server is in a rack, slide it far enough from the rack so that you can remove

the main cover and front cover. If you cannot safely view and access the
component, remove the server from the rack.

4. Remove the main cover as described in

Section 3.2.2, “Removing the Main Cover”

on page 3-3

.

5. Remove the front bezel as described in

Section 3.2.3, “Removing the Front Bezel”

on page 3-4

.

Note –

Always unfasten the bezel’s securing screw before removing the bezel.

6. Remove the front cover as described in

Section 3.2.4, “Removing the Front Cover”

on page 3-5

.

7. Remove all six fan modules by lifting each fan module by its plastic strap to

disconnect it from its fan connector board.

8. Remove both fan connector boards:

a. Unfasten the single screw that secures each fan connector board to the chassis.

See

FIGURE 3-27

.

TABLE 3-8

Sun Fire X4100 Supported Front I/O Board Part Numbers

Component

Part Number

Front I/O board (for Sun Fire X4100)

501-6918