Figure 4-57 – Sun Microsystems Sun Fire X4100 User Manual

Page 192

background image

4-62

Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006

The slots for the PCI cards are detected by the system BIOS during bootup in the
order described in

Section 2.3.2.1, “PCI Card Slot Booting Priority” on page 2-5

.

Note –

Before you install a card, consult the manufacturer's documentation for

system requirements and configuration information for your specific PCI card.

FIGURE 4-57

Sun Fire X4200 Designation and Speeds of PCI Slots

5. Remove any existing PCI card from the slot, or go to

Step 7

if the slot is empty:

a. Disconnect any external cables that are attached to the PCI card.

b. Working from the rear of the chassis, pivot open the PCI card latch that covers

the PCI card’s rear connector panel. See

FIGURE 4-58

.

FT1
FM0

FT1
FM1

FT1
FM2

FT0
FM0

FT1
FM1

FT1
FM2

CPU1

CPU0

Front panel of server

PCI1 = PCIX 133 MHz
PCI2 = PCIX 66 MHz
PCI3 = PCIX 66 MHz
PCI4 = PCIX 66 MHz

PCI0 = PCIX 100 MHz

0

1

4 3 2

PCI slots 0 - 4