Sun StorEdge A5000 and A5100 arrays are not supported.

TABLE 2-2

Sun StorEdge A5200 Array

Feature

Supported

Cascading

No

Zone type

SL zone only

Maximum number of arrays per SL zone

3

Maximum initiators per SL zone

2

Maximum initiators per array

4 (2 per loop)

Split loop support

No

TABLE 2-3

Sun StorEdge T3 Array and T3+ Array

Feature

Supported

Cascading

Yes

Zone Type

nameserver zone

1

, SL zone

1. The host must be connected to the F-Port on the switch; Sun StorEdge T3 array must be connected to the TL port

of the switch.

Maximum number of arrays per zone

8

Maximum initiators per LUN

2

Maximum initiators per zone

2

2

2. This implies 2 initiators (2 hosts) for simple arrays (T3WG), but 4 initiators (2 hosts) for a partner pair (T3ES).

Each host has one path to each of the Sun StorEdge T3 arrays in the partner pair.