Problems and corrective measures—error messages, Problems and corrective measures—switch, Problem – Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual
Page 170: Corrective measures
140
Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001
path and that the path is not available for a failover operation. Both paths of a dual
connected Sun StorEdge A5200 array are ONLINE. Only one path of a Sun StorEdge
T3 array is ONLINE; the other path is STANDBY.
■
Check that the
cfgadm
listing to verify
Ap_Ids
, representing Fabric-connected
Sun StorEdge T3 Array paths, are configured and in the normal condition.
■
Check
/var/adm/messages
or Network Storage Agent for any related errors
■
Check the SANsurfer GUI for error counters.
If the problem persists, contact your Sun Service representative.
Problems and Corrective Measures—Error
Messages
Problem
ONLINE/OFFLINE messages appear in
/var/adm/messages
or on the console.
Corrective Measures
■
Check the SANsurfer GUI port details for increasing error counters.
■
Run Stortools to test HBA status (
qlctest
).
■
Check Network Storage Agent for messages or events.
If the problem persists, contact your Sun Service representative.
Problems and Corrective Measures—Switch
Problem
You cannot connect to a switch with the SANsurfer GUI.
Corrective Measures
■
Verify that the switch is powered on and has an Ethernet cable connected to it.
■
Make sure the switch is not in Force Prom Mode.