beautypg.com

Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 134

background image

104

Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

Note –

The

luxadm

(1M) output on

50020f2300006107

will show the same

information as the previous display.

To Unconfigure a Fabric Device Associated With Sun
StorEdge Traffic Manager Devices

This example shows a Fabric-connected host ports c0 and c2 to illustrate how to
unconfigure Fabric devices associated with Sun StorEdge Traffic Manager devices.

Note –

Whether Sun StorEdge Traffic Manager is enabled or not, the unconfigure

operation for Fabric devices is identical but the result of the operation is different.
When the Sun Storage Traffic Manager software is enabled, the Solaris host creates
device node and path information that includes Sun StorEdge Traffic Manager
information.

1. Become superuser.

2. Identify the port WWN of the Fabric device to be unconfigured.

You can obtain port WWNs of Sun StorEdge T3 arrays by using the Sun StorEdge
Component Manager software.

/devices/scsi_vhci/ssd@g60020f20000061073ac8b4c50004ed3a:c,raw

Controller

/devices/pci@1f,2000/pci@1/SUNW,qlc@4/fp@0,0

Device Address 50020f2300006107,0

Class primary

State ONLINE

Controller

/devices/pci@1f,2000/pci@1/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006077,0

Class secondary

State STANDBY

CODE EXAMPLE 8-3

(Continued)