beautypg.com

Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 36

background image

6

Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

In a cascaded configuration, two switches are connected together via
InterSwitchLinks (ISL). A hard zone and a nameserver zone span both switches. All
hosts connected to these zones must be on one switch, and all storage must be on the
other. Cascaded switches are supported only for long distance, and long wave
GBICS are required between switches.

Note –

Only long wave Gigabit Interface Converters (LW GBIC) and cables are

supported for connecting the cascading switches. You must use LW GBIC and
corresponding LW fiber cable if you cascade more than 500 meters.

TABLE 2-1

Supported Hardware

Part Number

Description

540-4026

Sun StorEdge A3500FC FC-AL controller for Sun StorEdge
A3500FC array (with Sun StorEdge D1000 tray)

540-4027

Sun StorEdge A3500FC FC-AL controller for Sun StorEdge A3000
array (with Sun StorEdge RSM tray)

Sun StorEdge A5200 array

Sun StorEdge T3 array

X6799A

Sun StorEdge PCI Single Fibre Channel Network Adapter

X6727A

Sun StorEdge PCI Dual Fibre Channel Network Adapter+

X6798A

Sun StorEdge CPCI Dual Fibre Channel Network Adapter

X6731A

Gigabit Interface Converter (GBIC)

X7637A

Long Wave (LW) GBIC

X978A

15m fiber optic cable

X6746A

Sun StorEdge Network FC Switch-8 and Switch-16

SG-XSW16-
32P

Sun StorEdge Network FC Switch-16

Sun StorEdge L180 or L700 FC Tape Library