beautypg.com

Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 139

background image

Chapter 8

Configuring the SAN

109

To Configure All Fabric-Connected Devices on a Sun
StorEdge Traffic Manager Enabled Host Port

In this example, an attachment point id (Ap_Id) on a Fabric-connected host port is a
path to a Sun StorEdge Traffic Manager device. Configuring an attachment point ID
on a Sun StorEdge Traffic Manager device has already been configured through
another attachment point ID will result in an additional path to the previously
configured device; but, a new Solaris device is not created in this case. Note that a
new Solaris device is not created in this case. A Solaris device is created only the first
time an attachment point ID to a corresponding Sun StorEdge Traffic Manager
device is configured.

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2

/devices/scsi_vhci/ssd@g60020f20000061073ac8b52d000b74a3:c,raw

Controller

/devices/pci@1f,2000/pci@1/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006077,1

Class primary

State ONLINE

DEVICE PROPERTIES for disk: 50020f2300006077

Status(Port B): O.K.

Vendor: SUN

Product ID: T300

WWN(Node): 50020f2000006077

WWN(Port B): 50020f2300006077

Revision: 0117

Serial Num: Unsupported

Unformatted capacity: 558448.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c6t60020F20000061073AC8B4C50004ED3Ad0s2

/devices/scsi_vhci/ssd@g60020f20000061073ac8b4c50004ed3a:c,raw

Controller

/devices/pci@1f,2000/pci@1/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006077,0

Class secondary

State ONLINE

CODE EXAMPLE 8-6