Problem, Corrective measures – Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual
Page 167
![background image](/manuals/152182/167/background.png)
Chapter 10
Troubleshooting Tools and Resources
137
Corrective Measures
■
Check that the
/kernel/drv/scsi_vhci.conf
configuration is correct.
■
Make sure
mpxio-disable=no
is set.
■
Check
/var/adm/messages
for errors.
■
For Sun StorEdge T3 Array installations, make sure the
sys mp_support
setting
is set to
mpxio
.
If the problem persists, contact your Sun Service representative.
Problem
Failing a path (to secondary or to primary) does not succeed using Sun StorEdge
Traffic Manager.
Corrective Measures
■
Check the
luxadm
display output on the disk/LUN to verify that the secondary
path is STANDBY.
If the path is not STANDBY, it cannot be used as a failover path.