beautypg.com

Problem, Corrective measures – Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 167

background image

Chapter 10

Troubleshooting Tools and Resources

137

Corrective Measures

Check that the

/kernel/drv/scsi_vhci.conf

configuration is correct.

Make sure

mpxio-disable=no

is set.

Check

/var/adm/messages

for errors.

For Sun StorEdge T3 Array installations, make sure the

sys mp_support

setting

is set to

mpxio

.

If the problem persists, contact your Sun Service representative.

Problem

Failing a path (to secondary or to primary) does not succeed using Sun StorEdge
Traffic Manager.

Corrective Measures

Check the

luxadm

display output on the disk/LUN to verify that the secondary

path is STANDBY.
If the path is not STANDBY, it cannot be used as a failover path.