Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001
4. Verify that the selected Fabric device is configured.
Notice that the
Occupant
column of both
c0
and
c0::50020f2300006077
displays as configured, indicating that the
c0
port has a configured occupants and
that the
c0::50020f2300006077
device is configured.
The device is available on a Solaris host.
is an example of the
luxadm(1M) output. Notice that two devices,
/dev/rdsk/c0t50020F2300006077d0s2
and
/dev/rdsk/c0t50020F2300006077d1s2
,
are configured for the device represented by
c0::50020f2300006077
. This
indicates that the physical device represented by
c0::50020f2300006077
has two
LUNs configured.
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
fc-fabric
connected
configured unknown
c0::50020f2300006077 disk
connected
configured
unknown
c0::50020f23000063a9 disk
connected
unconfigured unknown
c0::50020f2300005f24 disk
connected
unconfigured unknown
c0::50020f2300006107 disk
connected
unconfigured unknown
c1
fc-private
connected
configured
unknown
c1::220203708b69c32b disk
connected
configured
unknown
c1::220203708ba7d832 disk
connected
configured
unknown
c1::220203708b8d45f2 disk
connected
configured
unknown
c1::220203708b9b20b2 disk
connected
configured
unknown
CODE EXAMPLE 8-1
# luxadm display 50020f2300006077
DEVICE PROPERTIES for disk: 50020f2300006077
Status(Port A): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f2000006077
WWN(Port A): 50020f2300006077
Revision: 0117
Serial Num: Unsupported
Unformatted capacity: 558448.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0