Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual
Page 128
98
Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001
4. Verify that all the devices on c0 are unconfigured.
Notice that the Occupant column of c0 and all the Fabric devices attached to it are
displayed as unconfigured.
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
fc-fabric
connected
unconfigured unknown
c0::50020f2300006077 disk
connected
unconfigured unknown
c0::50020f23000063a9 disk
connected
unconfigured unknown
c0::50020f2300005f24 disk
connected
unconfigured unknown
c0::50020f2300006107 disk
connected
unconfigured unknown
c1
fc-private
connected
configured
unknown
c1::220203708b69c32b disk
connected
configured
unknown
c1::220203708ba7d832 disk
connected
configured
unknown
c1::220203708b8d45f2 disk
connected
configured
unknown
c1::220203708b9b20b2 disk
connected
configured
unknown