beautypg.com

Code example 9-1, Table 9-1, Other /etc/path_to_inst device path entries – Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 160

background image

130

Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

CODE EXAMPLE 9-1

PCI Single Fibre Channel Network Adapter Device Path

3. Manually plumb the fp instance.

Use the

ifconfig

interface

plumb

command In this example, interface would be

fcip7..

If no error message is displayed, manual plumbing has succeeded. Repeat this step
for the other fp instances identified in Step 2.

Other

/etc/path_to_inst

Device Path Entries

The above procedure uses a a PCI single fibre channel network adapter device path
entry from the

/etc/path_to_inst

file.

CODE EXAMPLE 9-2

shows a device path

entry for a CPCI dual fibre channel network adapter.

CODE EXAMPLE 9-3

shows a

device path entry for a PCI dual fibre channel network adapter.

CODE EXAMPLE 9-2

CPCI Dual Fibre Channel Network Adapter Device Path

CODE EXAMPLE 9-3

PCI Dual Fibre Channel Network Adapter Device Path

“/pci@b,2000/SUNW,qlc@2/fp@0,0” 7 “fp”

TABLE 9-1

PCI Single Fibre Channel Network Adapter

/etc/path_to_inst

Device Path Entry

Entry Item

Entry Value

Physical Name

“pci@b,2000/SUNW,qlc@2/[email protected]

Instance Number

7

Driver Binding
Name

“fp”

# ifconfig fcip7 plumb

"/ssm@0,0/pci@19,700000/pci@2/SUNW,qlc@4/fp@0,0" 6 "fp"

"/pci@1f,4000/pci@4/SUNW,qlc@5/fp@0,0" 3 "fp"