beautypg.com

Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 126

background image

96

Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

Note –

Stop all device activity to each Fabric device on the selected port and

unmount any filesystems on each Fabric device. If the device is under any volume
manager’s control, see the documentation for your volume manager for maintaining
the Fabric device.

Note –

This operation repeats the configuration operation of an individual device

for all the devices on

c0

, and may be time consuming if the number of devices on

c0

is large.

4. Verify that all devices on

c0

are configured.

# cfgadm -c configure c0

# cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

c0

fc-fabric

connected

configured unknown

c0::50020f2300006077 disk

connected

configured unknown

c0::50020f23000063a9 disk

connected

configured unknown

c0::50020f2300005f24 disk

connected

configured unknown

c0::50020f2300006107 disk

connected

configured unknown

c1

fc-private

connected

configured

unknown

c1::220203708b69c32b disk

connected

configured

unknown

c1::220203708ba7d832 disk

connected

configured

unknown

c1::220203708b8d45f2 disk

connected

configured

unknown

c1::220203708b9b20b2 disk

connected

configured

unknown