beautypg.com

Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 142

background image

112

Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

4. Verify that all devices on c2 are configured.

Notice that the Occupant column of both c2 and all of the devices under c2 as
configured.

Compare the luxadm output in

CODE EXAMPLE 8-8

with that in

CODE EXAMPLE 8-7

on

page 110. Notice the addition of a new path to the Sun StorEdge Traffic Manager
device.

# cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

c0

fc-fabric

connected

configured unknown

c0::50020f2300006077 disk

connected

configured unknown

c0::50020f23000063a9 disk

connected

configured unknown

c1

fc-private

connected

configured

unknown

c1::220203708b69c32b disk

connected

configured

unknown

c1::220203708ba7d832 disk

connected

configured

unknown

c1::220203708b8d45f2 disk

connected

configured

unknown

c1::220203708b9b20b2 disk

connected

configured

unknown

c2

fc-fabric

connected

configured unknown

c2::50020f2300005f24 disk

connected

configured unknown

c2::50020f2300006107 disk

connected

configured unknown

CODE EXAMPLE 8-8

# luxadm display 50020f2300006077

DEVICE PROPERTIES for disk: 50020f2300006077

Status(Port A): O.K.

Status(Port B): O.K.

Vendor: SUN

Product ID: T300

WWN(Node): 50020f2000006077

WWN(Port A): 50020f2300006077

WWN(Port B): 50020f2300006107

Revision: 0117

Serial Num: Unsupported

Unformatted capacity: 558448.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2

/devices/scsi_vhci/ssd@g60020f20000061073ac8b52d000b74a3:c,raw