Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual
Page 132
102
Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001
3. Configure Fabric devices and create Sun StorEdge Traffic Manager devices.
4. Verify that the selected devices are configured.
Notice that the
Occupant
column of both
c0
and
c0::50020f2300006077
specifies configured, indicating that the
c0
port has configured occupants and that
the c0::50020f2300006077 device is configured. The same change has been made on
c2
and
c2::50020f2300006107
.
After the
cfgadm -c configure
command completes without an error, the Sun
StorEdge Traffic Manager devices are created on the Solaris host.
shows output for a Sun StorEdge T3 enterprise array. Notice that two Sun StorEdge
Traffic Manager devices,
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
and
/dev/rdsk/c6t60020F20000061073AC8B4C50004ED3Ad0s2
,
are created for the device represented by c0::50020f2300006077 and
c2::50020f2300006107. This indicates that the physical device represented by
c0::50020f2300006077 and c2::50020f2300006107 has two LUNs configured.
# cfgadm -c configure c0::50020f2300006077 c2::50020f2300006107
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
fc-fabric
connected
configured unknown
c0::50020f2300006077 disk
connected
configured
unknown
c0::50020f23000063a9 disk
connected
unconfigured unknown
c1
fc-private
connected
configured
unknown
c1::220203708b69c32b disk
connected
configured
unknown
c1::220203708ba7d832 disk
connected
configured
unknown
c1::220203708b8d45f2 disk
connected
configured
unknown
c1::220203708b9b20b2 disk
connected
configured
unknown
c2
fc-fabric
connected
configured unknown
c2::50020f2300005f24 disk
connected
unconfigured unknown
c2::50020f2300006107 disk
connected
configured unknown
CODE EXAMPLE 8-3
# luxadm display 50020f2300006077
DEVICE PROPERTIES for disk: 50020f2300006077
Status(Port A): O.K.
Status(Port B): O.K.