DAB1 DISTRIBUTED AUDIO SYSTEM

DAB1 Inbound Serial Commands

Each DAB1 inbound serial command begins with a colon character (:), followed by a single letter that indicates the desired
command, then one or more parameters, and ends with a carriage return ().

C

Coom

mm

maanndd

SSyynnttaaxx

PPaarraam

meetteerrss

SSttaattee

C

Coom

mm

meennttss

Zone Power

:Zxy

x = Zone 1 – 6; y = State

1 = On; 0 = Off

Discrete Zone Setting

All Zones Off

:Zy

y = State

1 = On; 0 = Off

Global Setting Only

Source Select

:Sxy

x = Zone 1 – 6; y = Source 1 – 4

Adjustable

Discrete Zone Setting

Tuner Preset

:Ryy

yy = Preset 1 – 12

Memory Preset #

Global Setting Only

Tuner Preset Step

:R++

++ = Next Preset

Adjustable

Requires Firmware v2.0

:R--

-- = Previous Preset

Adjustable

or higher

Tuner Band

:Ny

y = State

1 = FM; 0 = AM

Global Setting Only

Volume

:Vxyy

x = Zone 1 – 6; yy = Vol 0 – 60

Adjustable

Discrete Zone Setting

Volume Step

:Vx++

++ = increase 1 step

Adjustable

Discrete Zone Setting

:Vx--

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Page Volume

:Gxyy

x = Zone 1 – 6; yy = Vol 0 – 60

Adjustable

Discrete Zone Setting

Page Volume Step

:Gx++

++ = increase 1 step

Adjustable

Discrete Zone Setting

:Gx--

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Mute

:Mxy

x = Zone 1 – 6; y = State

1 = Mute On; 0 = Mute Off

Discrete Zone Setting

Balance

:Bxyyy

x = Zone 1 – 6; yyy = Bal -10 – +10

Adjustable; Center = 0

Discrete Zone Setting

Balance Bump Step

:Bx++

++ = increase 1 step to right

Adjustable

Discrete Zone Setting

:Bx--

-- = increase 1 step to left

Adjustable

Discrete Zone Setting

Bass

:Lxyy

x = Zone 1 – 6 yy = Bass -8 – +8

Adjustable; Flat = 0

Discrete Zone Setting

Bass Bump Step

:Lx++

++ = increase 1 step

Adjustable

Discrete Zone Setting

:Lx--

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Treble

:Hxyy

x = Zone 1 – 6; yy = Treble -8 – +8

Adjustable; Flat = 0

Discrete Zone Setting

Treble Bump Step

:Hx++

++ = increase 1 step

Adjustable

Discrete Zone Setting

:Hx--

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Simulate Button Press

:Pzxyyy

SSeeee SS

II M

M U

U LL A

A TT EE

BB

U

U TT TT O

O N

N

PP

RR EE SS SS

C

C

O

O M

M M

M A

A N

N D

D SS

oonn ppaaggee 4

48

8

After each command is received the DAB1 will respond with ‘+OK’ if the command is recognized and executed, or ‘+ERR’
if the command is invalid. Note that even valid commands will return ‘+ERR’ if the DAB1 is not able to process them
(i.e. if it is turned OFF).